Preheat temperature by the CET method, cooling time t8/5 forwards and backwards, heat input and dew point. Every calculation belongs to an order and component – with a printout for the file.
Enter carbon equivalent, plate thickness, hydrogen content and heat input – this is how WeldDeck calculates to EN 1011-2 (CET method). In the module you also get analysis, t8/5, SEW 088, dew point and the printout.
Result without guarantee – the standard, material manufacturer and your WPS are authoritative.
Carbon equivalent directly from the analysis – CET, CE, Pcm and CEN are calculated too. Hydrogen content selectable from the list.
t8/5 from heat input, preheat temperature and thickness – with transition thickness for 2D and 3D. Or the other way round: which heat input fits the target t8/5?
Dew point from hall temperature and humidity. Every calculation is stored on the component and can be printed with your company header.
All formulas are shown openly in the calculator – no value without derivation.
Calculations sit with the component – together with the acceptance limits sheet.
Everyone sees the same calculations – on PC, tablet or in the hall.
Register, create a component, calculate and print.
Already registered? Sign in